As far as I know, in VISSIM you just add some simulation time and
traffic demand during warm-up, too. There is no real difference compared
to SUMO. You can specify the simulation time with the time-related
parameters in SUMO: https://sumo.dlr.de/docs/sumo.html#time
<https://sumo.dlr.de/docs/sumo.html#time>
The only thing you have to bother with is simulation output: SUMO
detectors collect data from the first simulation step. In order to
separate data from warm-up period exactly, be sure to choose an
aggregation frequency as a factor of warm-up period (see e.g. induction
loop detectors
<https://sumo.dlr.de/docs/Simulation/Output/Induction_Loops_Detectors_(E1).html>
freq attribute): freq*n = warm-up period; where n is an integer.
Mirko
Am 30.12.2020 um 12:03 schrieb Shah Sultan:
Thank you Giuliana for your reply.
Do I need to set the warm-up period through Traci? or is there any other way
to set it once for my whole simulation run? Maybe you find this question
silly but previously I was using VISSIM in which I just needed to change
some attribute for that from the VISSIM interface.
--
Sent from: http://sumo-user-mailing-list.90755.n8.nabble.com/
_______________________________________________
sumo-user mailing list
sumo-user@eclipse.org
To unsubscribe from this list, visit
https://www.eclipse.org/mailman/listinfo/sumo-user
_______________________________________________
sumo-user mailing list
sumo-user@eclipse.org
To unsubscribe from this list, visit