The difference is caused by having two different simulations:
- The first simulation is run with traci control (traci.start, ...
traci.lane.setAllowed, ... traci.close() and reflects the use of the BPL
- The second simulation is run with subprocess.run and doesn't have the
BPL.

Your first simulation runs with the gui and your second simulation produces
the stop-output.
My advice is to add the --stop-output command to the sumoCmd for the first
simulation and dispense with the second simulation.

Am Sa., 13. Apr. 2024 um 07:09 Uhr schrieb Buddini Wanasooriya via
sumo-user <[email protected]>:

> Hello,
> As a new user of SUMO, I am currently engaged in an experiment to study
> the bus bunching phenomena and assess the feasibility of implementing a Bus
> Priority Lane (BPL) within SUMO's simulation environment.
> I have developed a sample network for this, considering two scenarios as
> follows.
>
>    1. Base scenario without a bus lane
>    2. BPL scenario with a bus lane
>
> I have generated the stop_output as the output file to identify bus
> bunching. The "started" attribute has been considered in that file, to
> identify the time at which buses are arriving at a certain bus stop.
> For the second scenario, the BPL has been activated via TraCI. However,
> the time recorded in the "started" attribute in stop_output here, is the
> same as the base scenario. When I compare it with the SUMO GUI, the time
> recorded in the stop_output is different from the observation of the
> simulation.
> I have attached a screenshot illustrating the arrival of "BUS_40" at bus
> stop "bs_0". While the timestamp recorded in the "started" attribute of the
> stop_output file indicates 1031, the corresponding timestamp displayed in
> the SUMO GUI is 402.
> Additionally, I attempted the BPL scenario without using TraCI by manually
> enabling the bus lane through the network file. From this method, I have
> obtained two different stop_output files for the two scenarios. It
> displayed the accurate "started" attribute that matches the SUMO GUI.
> The working folder containing all the generated stop_output files is
> attached herewith for your reference.
> Kindly assist in resolving this matter to effectively employ TraCI to
> ensure the recording of accurate timestamps in the stop_output file, for
> the BPL scenario.
>
> Thank You in advance.
> Regards,
> Buddini
> _______________________________________________
> sumo-user mailing list
> [email protected]
> To unsubscribe from this list, visit
> https://www.eclipse.org/mailman/listinfo/sumo-user
>
_______________________________________________
sumo-user mailing list
[email protected]
To unsubscribe from this list, visit 
https://www.eclipse.org/mailman/listinfo/sumo-user

Reply via email to