Okay, I realize this config may not be technically supported, but want
to know if it should work.

I have 3 sunray servers running SRSS 3.1 with Windows Connector
software.
I set up two of the servers on the same subnet in a failover group.
Everything works great.
Network config is no interconnect configuration, just using default IP
addresses with mulitcast for FoG communication.

A few days later attempt to add the third server to failover group.
This server is in another building on a different subnet.  Have verified
with network guys that multicast should route between across the WAN.

Run the utreplica -p -a on primary, and utreplica -s on secondary.  Also
run utfwsync on secondary.
Everything completes, no errors, but when I run utgstatus on the primary
server, it only shows it and the secondary on same subnet.  When I run
utgstatus on new secondary, it only shows itself.

Utreplica -l on primary does show all three servers, and when run on new
secondary it does show the correct primary.
Snooping the interface for multicast and port 7009 only shows multicast
packets staying on the same subnet.

My question is If I can work out with network team why multicast packets
aren't traversing the WAN then a WAN distributed FoG should work with
this setup correct?

Thanks,
Taylor