> ---------- Forwarded message ---------- > From: Andrey Filippov <[email protected]> > Date: Thu, May 5, 2011 at 1:19 PM > Subject: Re: [Elphel-support] RTSP & ( 2 x 353L ) over 24/7 = I x 353L works > OK, the other 353L problematic. > > There are several things that we can try. > > First of all - what do you do to reconnect? just restart the stream or you > have to power cycle the camera? Can you get images after the connection is > lost? Are they normal or broken?
I simply restart the connection from the VLC to the IP address:554. Only on a couple of occasions have I had to cold-reboot (power cycle) the camera. Generally, restarting the VLC connection connects probably 95% of the time. I will do a more exact measure and get better data back to you. > Do the failures depend on the temperature? (i.e. you can wrap the camera to > make it heat up faster)? Not that I have noticed. I have measured both with an external IR temp reader and there is little difference between them. > If it is just in one camera and especially if it is temperature dependent, > we can try different FPGA bitstream and see if it makes any difference. Thanks Andrey I will certainly give that a go too. I am currently interstate, but once back I give each camera a bigger/harder workout and see if I can get any differentiated result. I am also having issues with NFS between one camera and a regular Linux host. I will investigate further and get back to you ASAP. Cheers. Grahame _______________________________________________ Support-list mailing list [email protected] http://support.elphel.com/mailman/listinfo/support-list_support.elphel.com