On Tue, Sep 11, 2018 at 09:27:16AM -0500, David McGriffy wrote:

> Of course, the
> calibration filters for tetrahedral mics attempt to correct for this
> effect, but those filters more closely match the diffuse field average of
> all directions than the more extreme results in the direction of one
> capsule.

This is correct. There is nothing special about the on-axis directions
that would make them better or worse than any other direction.

Tetramics are calibrated for best frequency response in the cardinal
directions (X, Y, Z). This corresponds to a good compromise over all
directions.

-- 