Author: nwhitehorn Date: Sun May 29 20:46:53 2011 New Revision: 222463 URL: http://svn.freebsd.org/changeset/base/222463
Log: Add some error handling here: if a sensor returns an error code (a negative Kelvin temperature, which is impossible except for some contrived magnetic spin systems), use the previous measurement from that sensor instead of corrupting everything and randomly changing the fans or shutting off the machine. Modified: head/sys/powerpc/powermac/powermac_thermal.c Modified: head/sys/powerpc/powermac/powermac_thermal.c ============================================================================== --- head/sys/powerpc/powermac/powermac_thermal.c Sun May 29 20:04:02 2011 (r222462) +++ head/sys/powerpc/powermac/powermac_thermal.c Sun May 29 20:46:53 2011 (r222463) @@ -94,13 +94,17 @@ pmac_therm_manage_fans(void) struct pmac_fan_le *fan; int average_excess, max_excess_zone, frac_excess; int nsens, nsens_zone; + int temp; if (!enable_pmac_thermal) return; /* Read all the sensors */ SLIST_FOREACH(sensor, &sensors, entries) { - sensor->last_val = sensor->sensor->read(sensor->sensor); + temp = sensor->sensor->read(sensor->sensor); + if (temp > 0) /* Use the previous temp in case of error */ + sensor->last_val = temp; + if (sensor->last_val > sensor->sensor->max_temp) { printf("WARNING: Current temperature (%s: %d.%d C) " "exceeds critical temperature (%d.%d C)! " _______________________________________________ svn-src-all@freebsd.org mailing list http://lists.freebsd.org/mailman/listinfo/svn-src-all To unsubscribe, send any mail to "svn-src-all-unsubscr...@freebsd.org"