We are always lurking.

I checked the ticket, there are multiple answers already. However we need a 
third party engineer to measure the line, and as noted this cannot be arranged 
before monday.

I suggest to replace the patch cable too, before sending someone on site, to 
avoid unnecessary cost.

--
Fredy Künzler

> Am 12.09.2025 um 23:01 schrieb Philippe Huber via swinog 
> <[email protected]>:
> 
> Hi List
> 
> Is someone from Init7 arround? We have some very high input noise, maybe the 
> patch connection in the POP is faulty.
> Ticket ID 42324217
> It would be great if someone can have a look.
> 
> Thanks and greetings from Pratteln
> 
> 
> Philippe
> _______________________________________________
> swinog mailing list -- [email protected]
> To unsubscribe send an email to [email protected]
_______________________________________________
swinog mailing list -- [email protected]
To unsubscribe send an email to [email protected]