Thanks for suggestion. I am sure that one storage node was unplugged. It should be similar as what Myckel suggested. Is there a fix for this? Thanks.
Best Regards, Yonggang On Thu, Nov 25, 2010 at 10:43 AM, Myckel Habets <[email protected]> wrote: > Could be the same thing that I saw happening in bug #68. > Pull one storage node out and the gateway still tries to connect to it, > blocking the whole client. > > >> Dear All: >> >> I am experiencing an issue with unplugging one node from my private >> grid. Here is my testbed: >> >> 1) 5 storage nodes >> 2) N=5, K=3 >> 3) two clients running on my laptops >> >> It has been working fine for normal operations. Then, I thought it >> should continue to work even if >> I unplug two nodes out of the grid. However, I cannot connect to the >> grid from either of the clients after >> I unplug only one Ethernet cable. >> >> Has anyone else seen similar issue? Thanks. >> >> Best Regards, >> Yonggang >> _______________________________________________ >> tahoe-dev mailing list >> [email protected] >> http://tahoe-lafs.org/cgi-bin/mailman/listinfo/tahoe-dev >> > > > _______________________________________________ > tahoe-dev mailing list > [email protected] > http://tahoe-lafs.org/cgi-bin/mailman/listinfo/tahoe-dev > > _______________________________________________ tahoe-dev mailing list [email protected] http://tahoe-lafs.org/cgi-bin/mailman/listinfo/tahoe-dev