Greetings,

Key "@_AUTOCLOSE" is a feature used when an "external program" is used to
connect to the application - for instance connecting to McKesson's HBOWem.

This says "close" the external program when whatever it is connected to goes
away. For some specific situations this is not what you want actually, hence
the feature to control this behavior.

 

This is not the case with Meditech. 

 

Since a BWS script needs to launch Meditech in order to connect - there is
no need for Key "@_AUTOCLOSE" in a Meditech script, since when Meditech goes
away, so does the "thing" that is talking to it. Shutdown=True says I am
going to close Boston WorkStation - completely unrelated to Key
"@_AUTOCLOSE".

 

By the way, incase you were wondering why @_AUTOCLOSE is sent via a key
command. What this is actually doing is sending an instruction over the
connection, a configuration mechanism if you will. There are actually many
such configurations - most are quite esoteric and specific to certain types
of connections.

 

A search in the help for @_ Commands will give you a listing of all of them
and what they do in case I've peaked your curiosity.

 

Regards,

Thom

 

Thom C. Blackwell

Product Manager

Boston Software Systems

(866) 653-5105 ex 807

www.bossoft.com <http://www.bossoft.com/> 

 

Sign <http://www.bostonworkstation.com/customer_center/special_events.aspx>
up for my weekly webinar!

 

LEGAL NOTICE Unless expressly stated otherwise, this message is confidential
and may be privileged. It is intended for the addressee(s) only. Access to
this E-mail by anyone else is unauthorized. If you are not an addressee, any
disclosure or copying of the contents of this E-mail or any action taken (or
not taken) in reliance on it is unauthorized and may be unlawful. If you are
not an addressee, please inform the sender immediately, then delete this
message and empty from your trash.

 

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Thompson, Mary
Sent: Tuesday, December 18, 2007 9:42 AM
To: [email protected]
Subject: RE: [Talk] Closing BWS

 

Would this be correct? And if I do this, do I need the  "Always SHUTDOWN =
TRUE".  Or does the Autoclose take care of all of it?

Thank you!

Mary

 

 

        If Not Active(MeditechSessionName) Then

            Connect "C:\Program Files\Meditech 3.24\t.exe", stMeditech,
MeditechSessionName 

Key"@_AUTOCLOSE"

        Else

            Connect MeditechSessionName, stStream

            Key "@_AUTOCLOSE"

        End If

 

Mary Thompson

Children's Mercy Hospital

Sr. Programmer Analyst

(816) 983 - 6977

  _____  

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Thom C. Blackwell
Sent: Tuesday, December 18, 2007 8:35 AM
To: [email protected]
Subject: RE: [Talk] Closing BWS

 

Greetings,

Directly after your Connect "sessionname", stStream command use:

Key "@_AUTOCLOSE"

Regards,

Thom

 

Thom C. Blackwell

Product Manager

Boston Software Systems

(866) 653-5105 ex 807

www.bossoft.com <http://www.bossoft.com/> 

 

Sign <http://www.bostonworkstation.com/customer_center/special_events.aspx>
up for my weekly webinar!

 

LEGAL NOTICE Unless expressly stated otherwise, this message is confidential
and may be privileged. It is intended for the addressee(s) only. Access to
this E-mail by anyone else is unauthorized. If you are not an addressee, any
disclosure or copying of the contents of this E-mail or any action taken (or
not taken) in reliance on it is unauthorized and may be unlawful. If you are
not an addressee, please inform the sender immediately, then delete this
message and empty from your trash.

 

From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of Walker, Reese
Sent: Tuesday, December 18, 2007 9:23 AM
To: [email protected]
Subject: [Talk] Closing BWS

 

The last step of all my scripts includes "Always SHUTDOWN = TRUE".  This
will close BWS, but not always the HBOWem Server Connection Streamer Thingy
(at least that is what I like to call it) in the bottom right hand corner
(Little Black B).  Is there something I can code that will always shut this
down as well?

 

Thanks,

 

Reese

 

Reese E. Walker
Financial Systems Analyst
Phoebe Putney Memorial Hospital
Albany, GA. 31702
Phone: (229) 312-4259
Pager: (229) 431-7658
Fax: (229) 312-4316

 

  _____  

 


Disclaimer:
The HIPAA Final Privacy Rule requires covered entities to safeguard
certain Protected Health Information (PHI) related to a person's
healthcare. Information being faxed to you may include PHI after
appropriate authorization from the patient or under circumstances
that do not require patient authorization. You, the recipient, are
obligated to maintain PHI in a safe and secure manner. You may not
re-disclose without additional patient consent or as required by
law. Unauthorized re-disclosure or failure to safeguard PHI could
subject you to penalties described in federal (HIPAA) and state
law. If you the reader of this message are not the intended
recipient, or the employee or agent responsible to deliver it to
the intended recipient, please notify us immediately and destroy
the related message.

Reply via email to