On jeu, 2007-01-18 at 22:55 +0100, Xavier Claessens wrote: > On jeu, 2007-01-18 at 21:39 +0000, Dafydd Harries wrote: > > Ar 18/01/2007 am 22:30, ysgrifennodd Xavier Claessens: > > > 1) RequestConnection returns the existing object if it's already > > > connected. Currently if I try to connect an account that is already > > > connected I get this error: > > > > > > * (gossip:6771): WARNING **: Connect() failed: Error acquiring bus name > > > org.freedesktop.Telepathy.Connection.idle.irc.xclaesse_irc_freenode_net, > > > The connection manager already has this connection active. > > > > Why not just call RequestConnection and catch the error to determine whether > > the connection exists? If you don't need the resulting connection object, > > you > > can just call Disconnect() on it. > > It can be a solution if all CM returns the same error. So there is three > solutions: > > 3) Add in the spec a possible error on RequestConnection telling it's > already connected. >
Hum after some thinking, return an error isn't that useful. It just tells the client that a connection exists but it doesn't says the object's path on the bus. Xavier.
signature.asc
Description: This is a digitally signed message part
_______________________________________________ Telepathy mailing list [email protected] http://lists.freedesktop.org/mailman/listinfo/telepathy