> looking at the UIS official symbols ...
> ceiling meander is shown with ticks outside,
> therion ceiling-meander draws with ticks pointing inside.
>
> also chinmey line in UIS is dashed with ticks.
> in therion is just dashed.
> (therion ceiling-step line is dashed with ticks).

In fact both problematic symbols are defined in SKBB (our local caving
group) symbol set.

Unfortunately, UIS set is incomplete in therion and missing symbols
are taken fom other symbol sets even if you select UIS set in
thconfig, as it is in this case. We can add those two symbols in the
next snapshot, other symbols upon request.

You can display an overview of currently defined symbols for all
symbol sets by running

therion --print-symbols

which creates symbols.xhtml file (you can display it in Firefox).

Martin