Hi: Problem solved.
The Ultra Stable Oscillator coarse tuning pot needed adjustment. Once it was adjusted to put the strong center peak into the center of the control voltage range s/n 1013 locked right up. This procedure is described in appendix A of the manual. But the procedure for the S/24 is much easier since the coarse tuning pot is on top of the USO, not on the inaccessible front like on earlier 4060 models that require removing the USO to get access to the pot. Now back to the regularly scheduled data logging. Having Fun, Brooke -- w/Java http://www.PRC68.com w/o Java http://www.pacificsites.com/~brooke/PRC68COM.shtml http://www.precisionclock.com _______________________________________________ time-nuts mailing list [email protected] https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts