Jim Miller schrieb:
>> i have a problem with my HP10811 ocxo. I connected it properly to 24V, 12V 
>> and to my counter to measure its frequency. The measured frequency is 10.887 
>> MHz, but it should be 10MHz (also noted on the 10811). A 5MHz tcxo is 
>> measured correctly, so i think the counter is okay. Can anyone help me ?
> 
> There is a thermal fuse on the oven control board which sometimes
> blows due to age, or it vibrates out, or otherwise fails.  This causes
> the oven to not operate and the unit is guaranteed to be off frequency
> by a large amount.

Wow, it's interesting to see what "large amount" means to different
folks.

To some, it's a few parts per billion.

To others, it's nearly 10% (umm, ninety million parts per billion).

Tim.

_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to