Brian Kirby wrote: > App Notes for good reading > > Linear Technology - LTZ1000 > AN86 Standards Lab Grade 20 Bit DAC with 0.1 PPM drift > AN82 Understanding and Applying Voltage References > AN42 Voltage Reference Collection > DN229 ABout long term testing > > National Semiconductor LM399 > AN-161 1 PPM voltage reference > AN-173 IC Zener eases reference design > AN-184 References for A/D COnvertors > > Xicor X60008A-50 > AN177 > > The Xicor references are very noisy and their relatively large flicker noise probably precludes them from use in high precision applications.
Bruce _______________________________________________ time-nuts mailing list -- [email protected] To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.