A lot depends upon the temperature sensor in the Tbolt.    Dallas Semi changed 
the guts of the sensor ship in such a way that the Tbolt can only get 1 degree 
resolution out of it.   Later production Tbolts all have that sensor.  Does 
your Tbolt show a mostly flat line temp curve with coarse,  step-like 
transitions or one that tracks the temperature rather finely?   When you hit 
the thing with the hot air,  what did the temperature plot do?

Also,  the temperature sensor would do no good inside the OCXO (there is 
already one in there).  The Tbolt temperature sensor is used to compensate the 
unit for temperature effects on the unit as a complete system.   It is also 
used for environmental alarms, etc.

----------------------------------------

                                          
_________________________________________________________________
Hotmail: Powerful Free email with security by Microsoft.
http://clk.atdmt.com/GBL/go/171222986/direct/01/
_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to