> Trying to run LH2 with a TBolt under WinXP. I need to change her com port to 3, > which is where my serial-to-USB adapter is located -- and port 1 is in use. > > I see in the "tip" sheet that I can use the command line. Trouble is, I can't find > it. Hitting most keys will display a menu of letters to invoke various things, but I > can't get to anything that looks like a command line to use the /3 command. > Suggestions?
This is just referring to the DOS command that you use to launch heather.exe, whether from a Windows shortcut or from a command prompt in a DOS box. If you are running from a shortcut, you would right-click on the shortcut and modify the 'Target' line to include the parameter(s) you want the program to start with. To connect to specific Thunderbolts at startup time, change the Target line from this: "C:\Program Files\Heather\heather.exe" ... to one that looks like this: "C:\Program Files\Heather\heather.exe" /3 (local Thunderbolt on COM3) or "C:\Program Files\Heather\heather.exe" /ip=ke5fx.dyndns.org:45000 (remote Thunderbolt attached to a Heather server, version 3 only) -- john, KE5FX > -----Original Message----- > From: time-nuts-boun...@febo.com [mailto:time-nuts-boun...@febo.com] On > Behalf Of Dick Moore > Sent: Monday, September 12, 2011 11:45 PM > To: time-nuts@febo.com > Subject: [time-nuts] Lady Heather help, please > > > TIA, > Dick Moore > _______________________________________________ > time-nuts mailing list -- time-nuts@febo.com > To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time- > nuts > and follow the instructions there. _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.