Lady Heather has a command line option that causes it to send an initialization 
string to the tbolt.

Try adding  "=10,3c,10,03" (without the quotes) to the command line.  Perhaps 
repeat the four hex values a few times.  There is no 300 msec delay command.

There is also a   "$10,3c,10,03" (without the quotes)  command line option that 
sends a string of hex bytes to the tbolt whenever the time message is received
There is also a /* command line option that attempts to get units that do not 
support the once per second automatic broadcast of the time message.
                                          