i use an Agilent 53132A as a TIC and Uli's "Plotter" to analyze the time interval data of two oscillators. after removing the cycle wraps and the drift there often remains a repeating pattern that i have not been able to explain, e.g. TI increases, then drops a little bit and starts to increase again, etc.

autocorrelating the data reveals clear and nice peaks. today i noticed that the distance between two peaks is equal to the time from one cycle wrap to the next.

it is obvious that using frequency dividers and avoiding cycle wraps would eliminate or at least reduce the problem. but of course i'd like to understand why this problem arises. any hint will be very much appreciated!