Em 02/07/2014 05:04, Hal Murray escreveu:
If you want to go farther or faster, it's probably wise to shift to differential signaling.

This. always use 485/422 drivers (2 pairs, one in each direction) + 1 pair for VCC + 1 pair for GND in a CAT-5 cable. If you are carefull you can choose the pinout in a way that if someone plugs it into an ethernet port it won´t blow anything. The limit becomes the power, because the 485 can drive >1200 meter cable if you use a good tranceiver (i´ve tried 600m, it works flawlessy).

Daniel
_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to