Good evening all,

After getting my RS-422 interface sorted and my remote serial to TCP configured, I am now able to connect to my KS-24361 boxes from a Win7 machine using a number of different applications to my LINUX box to which the 24361 is physically connected.

On the LINUX box I am using ser2net and on the Win 7 box com0com and com2tcp. The HP SATSTAT program connects quite nicely to the 24361 this way as does using telent and a TERMITE (a terminal emulation program) and manually entering commands. I can post more details if someone needs a bit more detail.

Also, I followed someones earlier suggestion of trying Ulrich's Z38XX program by editing with a HEX edition the values for Z3805 and changing them to something appropriate. I did just this and changed Z3805 to Z3812 (in two places) and the program works very well connecting to and now quite happily querying the KS-24361 boxes and plotting data.

cheers, Graham ve3gtc



_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.