Dear all, Do any one still using Cisco 7200 as NTP master? and get ref clock from Microsemi GPS TOD via Aux port
I used to have a TimeSource3600 to feed TOD to a Cisco7204VXR, but the TS3600 was dead, and I TimeSource3550 was installed. But I found the 7204 cannot get a reliable PPS from the TS3550. In 7204, I use below command: line aux 0 ntp refclock telecom-solutions pps cts stratum 0 no exec transport input all stopbits 1 line vty 0 4 exec-timeout 20 0 ! ntp access-group query-only 95 ntp access-group peer 96 ntp access-group serve 97 ntp access-group serve-only 98 ntp master In TS3550, I set the TOD format to Cisco, and a TOD converter was installed. The 7204 can sync to GPS after a reboot. but after some time (form min. to an hour) it will lost sync to GPS and said "Bad Time" or "No PPS signal" in sh ntp asso detail" and sh line aux wil indicate alot of "noise" & "overrun" ==== 7204 ==== sh ntp ass de 127.127.7.1 configured, our_master, sane, valid, stratum 7 ref ID 127.127.7.1, time D8212701.14C20B50 (12:28:49.081 HKT Thu Nov 27 2014) our mode active, peer mode passive, our poll intvl 64, peer poll intvl 64 root delay 0.00 msec, root disp 0.00, reach 377, sync dist 0.015 delay 0.00 msec, offset 0.0000 msec, dispersion 0.02 precision 2**18, version 3 org time D8212701.14C20B50 (12:28:49.081 HKT Thu Nov 27 2014) rcv time D8212701.14C20B50 (12:28:49.081 HKT Thu Nov 27 2014) xmt time D8212701.14C1C10F (12:28:49.081 HKT Thu Nov 27 2014) filtdelay = 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 filtoffset = 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 filterror = 0.02 0.99 1.97 2.94 3.92 4.90 5.87 6.85 Reference clock status: Running normally Timecode: --More-- 127.127.6.1 configured, insane, invalid, unsynced, stratum 0 ref ID .GPS., time 00000000.00000000 (08:00:00.000 HKT Mon Jan 1 1900) our mode active, peer mode unspec, our poll intvl 64, peer poll intvl 64 root delay 0.00 msec, root disp 0.00, reach 0, sync dist 103.516 delay 0.00 msec, offset 0.0000 msec, dispersion 16000.00 precision 2**20, version 3 org time 00000000.00000000 (08:00:00.000 HKT Mon Jan 1 1900) rcv time 00000000.00000000 (08:00:00.000 HKT Mon Jan 1 1900) xmt time D8212733.14C1CF13 (12:29:39.081 HKT Thu Nov 27 2014) filtdelay = 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 filtoffset = 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 filterror = 16000.0 16000.0 16000.0 16000.0 16000.0 16000.0 16000.0 16000.0 Reference clock status: No PPS signal Timecode: *,A,56989,14/11/27,04:29:47,+00.0,0,22N22.238,114E07.820,+0095 sh lin aux 0 Tty Typ Tx/Rx A Modem Roty AccO AccI Uses Noise Overruns Int * 1 AUX 9600/9600 - - - - - 0 581 1/799854 - Line 1, Location: "", Type: "" Length: 24 lines, Width: 80 columns Baud rate (TX/RX) is 9600/9600, no parity, 1 stopbits, 8 databits Status: Ready, Active, Modem Signals Polled Capabilities: EXEC Suppressed, NTP Reference Clock, PPS Reference Clock Modem state: Ready Modem hardware state: CTS* noDSR DTR RTS Special Chars: Escape Hold Stop Start Disconnect Activation ^^x none - - none Timeouts: Idle EXEC Idle Session Modem Answer Session Dispatch 00:10:00 never none not set Idle Session Disconnect Warning never Login-sequence User Response 00:00:30 Autoselect Initial Wait not set Modem type is unknown. Session limit is not set. Time since activation: never Editing is enabled. History is enabled, history size is 10. DNS resolution in show commands is enabled Full user help is disabled Allowed input transports are pad v120 telnet. Allowed output transports are pad v120 telnet. Preferred transport is telnet. No output characters are padded No special data dispatching characters ==== End ==== I had replace the 7204, reboot the TS3550, replace TOD converter and related cable.but no luck. Any idea? Dear Mark Allwright, Can I have your "Application Note 600"? Thanks in advance for any suggestion. Best Reg. Bob _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.