I can't help but notice that there is an impact on the measured phase error 
every time the TDOP reported by the LEA-6T changes.  What I don't know is how 
to characterize the impact.  Is the impact more of a change in the error band, 
rather than a bias in one direction or the other?  Would a variable dead-band 
filter be an appropriate response to these changes?  I've experimented with a 
dead-band filter in the past with mixed results, but I never coupled the width 
of the dead-band to the TDOP.

Bob - AE6RV -----------------------------------------------------------------
AE6RV.com

GFS GPSDO list:
groups.yahoo.com/neo/groups/GFS-GPSDOs/info
_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.

Reply via email to