I can't help but notice that there is an impact on the measured phase error every time the TDOP reported by the LEA-6T changes. What I don't know is how to characterize the impact. Is the impact more of a change in the error band, rather than a bias in one direction or the other? Would a variable dead-band filter be an appropriate response to these changes? I've experimented with a dead-band filter in the past with mixed results, but I never coupled the width of the dead-band to the TDOP.
Bob - AE6RV ----------------------------------------------------------------- AE6RV.com GFS GPSDO list: groups.yahoo.com/neo/groups/GFS-GPSDOs/info _______________________________________________ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.