Hi Pete,
I have a NTBW50AA running with Lady Heather 5.0 (and also with previous
version) and I don't see any anomaly, it sees all satellites in view and
the clock updates every second. BTW, I have done a mod for outputting 1
PPS instead of 1/2 PPS, but it does not go to LH.
I can only suggest you to test it using Trimble Visual Timing Studio to
have a "second opinion".
Regards,
Ignacio, EB4APL
El 05/01/2017 a las 15:25, Peter Reilley escribió:
I just got my Trimble NTBW50AA GPSDO up and running with Lady Heather
5.0.
However I don't see any satellite data as I do with my Resolution T.
I am using
/rxy which specifies SCPI-(NORTEL) as the device.
What am I doing wrong?
Also, the clock updates every 2 seconds. I assume that this is an
artifact of the
2PPS output.
Thanks,
Pete.
_______________________________________________
_______________________________________________
time-nuts mailing list -- time-nuts@febo.com
To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts
and follow the instructions there.