-------- In message <d270c1c1-6704-660a-a8ff-ee3b3616f...@rubidium.dyndns.org>, Magnus D anielson writes:
>> measure (start=house_std, stop=siggen) and (start=siggen, stop=house_std) for >> as many siggen phase settings as you have patience for. > >Well, this was the second setup I was talking about. To disclose the >full non-linearity you want to tweak it to 9.999 MHz rather than 10 MHz. Yes, that is a fall-back if your siggen cannot control the phase. Of course if you both set 9.999 MHz *and* sweep the phase, you will be able to separte the effects of the siggen and counter even better. -- Poul-Henning Kamp | UNIX since Zilog Zeus 3.20 p...@freebsd.org | TCP/IP since RFC 956 FreeBSD committer | BSD since 4.3-tahoe Never attribute to malice what can adequately be explained by incompetence. _______________________________________________ time-nuts mailing list -- time-nuts@lists.febo.com To unsubscribe, go to http://lists.febo.com/mailman/listinfo/time-nuts_lists.febo.com and follow the instructions there.