OPTIONAL 1 PP2S OUTPUT
(EVEN-SECOND OUTPUT)
An even-second (1 PP2S) output is
available as an option to the 58503B.
The even-second output option
provides one pulse every other second,
synchronized to the even seconds in
GPS time. This is the reference time
used in CDMA base stations. GPS evensecond
pulses from the 1 PP2S option
are used to synchronize the AgilentĀ®
8921A (Option 600) and the Agilent
8935A cellular base station test sets.
Synchronizing the test set from an
independent source permits remote base
station testing and independent base
station frequency and time reference
accuracy checks.