Hello, We're suffering from sporadic network blockage(read: unable to ping other nodes) with 1.1-pre17. Before upgrading to the 1.1-pre release, the same network blockage also manifested itself in a pure 1.0.33 network.
The log shows that there are a lot of "Got ADD_EDGE from nodeX (192.168.0.1 port 655) which does not match existing entry" and it turns out that the mismatches were cuased by different weight received by add_edge_h(). This network is consists of ~4 hub nodes and 50+ leaf nodes. Sample hub config: Name = hub1 ConnectTo = hub2 ConnectTo = hub3 ConnectTo = hub4 Leaf looks like: Name = node1 ConnectTo = hub1 ConnectTo = hub2 ConnectTo = hub3 ConnectTo = hub4 Back to the days of pure 1.0.33 nodes, if the network suddenly fails(users will see tincd CPU usage goes 50%+ and unable to get ping response from the other nodes), we can simply shutdown the hub nodes, wait for a few minutes and then restart the hub nodes to get the network back to normal; however, 1.1-pre release seems to autoconnect to non-hub hosts based on the information found in /etc/tinc/hosts, which means that the hub-restarting trick won't work. Additionally, apart from high CPU usage, 1.1-pre tincd also starts hogging memory until Linux OOM kills the process(memory leakage perhaps?). Given that many of our leaf nodes are behind NAT thus there's no direct connection to them expect tinc tunnel, I'm wondering about if there's any way to bring the network back to work without shutting down all nodes? Moreover, is there any better way to pin-point the offending nodes that introduced this symptom? Thanks, A. _______________________________________________ tinc mailing list [email protected] https://www.tinc-vpn.org/cgi-bin/mailman/listinfo/tinc