On Aug 23, 2006, at 8:04 AM, R. Steve McKown wrote:
On Wednesday 23 August 2006 03:40 am, Jay Taneja wrote:
... it runs into
errors when working with Collection, which has a StdControl interface
(which has start(), and stop() functions). The problem is that I have
implemented AMControl.startDone() and stopDone() events in
MySenderP (for
the Serial interface). However, these events aren't present in the
Collection StdControl interface and the compiler complains thusly.
[snip]
Any suggestions for getting around this? Thanks for the help.
One solution is to wrap the Collection's StdControl interface in a
custom
component implementing SplitControl. Maybe something a bit like this:
Calling Collection.StdControl.start does NOT start the radio. It
starts the collection service.
You have to separately start the radio and collection.
Phil
_______________________________________________
Tinyos-help mailing list
Tinyos-help@Millennium.Berkeley.EDU