Thomas,

Thanks alot for your valuable feedback, atleast I know that I have to try
harder on that, but one small catch, I ma using Ubuntu12.04, can this be
the reason, not sure but need to look into it in more detail.

Thanks!

Regards,
Wasif!

On Tue, Jan 15, 2013 at 4:02 PM, Thomas Schmid <thomas.sch...@gmail.com>wrote:

> We successfully had about 150 telosb nodes connected to one Linux laptop.
> The theoretic USB limit is 127 devices, including hubs, per bus. Usually
> your computer has multiple buses. We actually tried to have 200 connected,
> but Linux didn't want to enumerate all of them and stopped at about 150. We
> had a tree topology of one 10 port hub connected to 5 other 10 port hubs.
> We had 4 of these configurations, each on an individual USB port on the
> laptop.
>
> In your case, I suspect a bad cable could be the problem? Or if you rub
> On Jan 15, 2013 7:52 AM, "Constantinos Marios Angelopoulos" <
> aggel...@gmail.com> wrote:
>
>> Hi guys,
>>
>> in one of our work here (
>> http://www.hobnet-project.eu/files/papers/Experimental_Evaluation_of_Energy_Balance.pdf)
>> we have connected 27 TelosB motes via a USB tree topology.
>>
>> The PC was running on Ubuntu 10.04.
>>
>> Regards,
>> Marios
>> --
>> Constantinos Marios Angelopoulos
>>
>> Department of Computer Engineering & Informatics
>> University of Patras and CTI & Press "Diophantus"
>>
>>
>>
>> On Tue, Jan 15, 2013 at 10:33 AM, Antonio Liñán C. 
>> <ali...@zolertia.com>wrote:
>>
>>> I think you hit a magic number, I haven't done this test myself, are you
>>> connecting all motes to the same hub or how are you grouping the motes?
>>>
>>> I'll try this on the afternoon for the kicks :)
>>>
>>> --Antonio
>>>
>>> On Mon, 2013-01-14 at 23:12 +0100, wasif masood wrote:
>>> >
>>> >
>>> > Dear All,
>>> >
>>> >
>>> > Does any of you have ever experienced about how many sensor nodes we
>>> > can attach to a PC. In my experience, using external powered USB hubs,
>>> > one can get as many connections as could but when it comes to serial
>>> > logging, not all the nodes can get their data to the BaseStation via
>>> > serial connection. Yesterday, I tired upto 10 and they worked just
>>> > fine, but if I try to increase them beyond 10 some nodes just
>>> > meteriously can't log any thing.
>>> >
>>> > Please share your experieces!
>>> > Regards!
>>> > Wasif Masood
>>> >
>>> > _______________________________________________
>>> > Tinyos-help mailing list
>>> > Tinyos-help@millennium.berkeley.edu
>>> >
>>> https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
>>>
>>>
>>> _______________________________________________
>>> Tinyos-help mailing list
>>> Tinyos-help@millennium.berkeley.edu
>>> https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
>>>
>>
>>
>> _______________________________________________
>> Tinyos-help mailing list
>> Tinyos-help@millennium.berkeley.edu
>> https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
>>
>
> _______________________________________________
> Tinyos-help mailing list
> Tinyos-help@millennium.berkeley.edu
> https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help
>



-- 
Wasif Masood
_______________________________________________
Tinyos-help mailing list
Tinyos-help@millennium.berkeley.edu
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help