Dear all, I want to measure the current consumption of MicaZ when Transmission Power is set to different values like 0dBm, -3dBm, ... -25dBm and compare my measurements with data sheet of MicaZ. for this aim I prepared a code. In this code the transmitter mode is activated and receiver mode is deactivated. There is no sensor board on the mote and all of the LEDs are turned off. and Micaz is broadcasting its node ID. The code is working fine for different Transmission Power settings. it means that when I set the Output Power to various mode the data is receivable at different distance.
My question : for different Transmission Power settings the measured current is about 22.9mA when sending packet and 22mA when not sending data. but according to datasheet for different Transmission Power settings we should have different current consumption. could you please help to find out the problem? With Best Regards, ---- Sajjad Baghaee
_______________________________________________ Tinyos-help mailing list Tinyos-help@millennium.berkeley.edu https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help