Hi,
stable microsecond accuracy is not possible because the clock itself 
drifts to much. With 30 ppm clock drift, you get a timing error of 1.8 
ms every minute. Better is only possible with external hardware support 
(e.g. a TXCO).

Greetings,
Florian Meier

On 25.01.2016 23:41, Ashikahmed Bhuiyan wrote:
> Hi,
>
> Can anyone please tell me how to achieve *Microsecond Accuracy in FTSP
> with telosb *devices?
>
> With Regards
> *Ashik Ahmed Bhuiyan
> *