Hi Brad, The TIPC that was out with VxWorks 6.2 used an older version numbering scheme. That version is closer to the TIPC 1.3.x numbering used in the open source version of TIPC.
I would suggest upgrading the VxWorks 6.2 to use TIPC 1.7.5. But even if you do not upgrade, you should be able to establish links between the linux box and the VxWorks box. You won't be able to use a number of features: - stream sockets - multi-cast - tipcConfig / tipc-config Good luck on your endeavours. Elmer -----Original Message----- From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED] On Behalf Of Brad Stephens Sent: Tuesday, March 11, 2008 3:50 PM To: [email protected] Subject: [tipc-discussion] TIPC version in vxWorks 6.2 I'm working on getting TIPC 1.7.5 on a linux box talking with a vxWorks board running vxWorks 6.2. I understand that the TIPC version on vxWorks 6.2 is described as version 1.2. I had heard that this was an "old" versioning mechanism and that it is actually based on TIPC 1.5.x. Is this the case? Thanks, Brad ------------------------------------------------------------------------- This SF.net email is sponsored by: Microsoft Defy all challenges. Microsoft(R) Visual Studio 2008. http://clk.atdmt.com/MRT/go/vse0120000070mrt/direct/01/ _______________________________________________ tipc-discussion mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/tipc-discussion