In commit 6f00089c7372 ("tipc: remove SS_DISCONNECTING state") the check for socket type is in the wrong place, causing a closing socket to always send out a FIN message even when the socket was never connected. This is normally harmless, since the destination node for such messages most often is zero, and the message will be dropped, but it is still a wrong and confusing behavior.
We fix this in this commit. Reviewed-by: Parthasarathy Bhuvaragan <parthasarathy.bhuvara...@ericsson.com> Signed-off-by: Jon Maloy <jon.ma...@ericsson.com> --- net/tipc/socket.c | 24 +++++++++++++----------- 1 file changed, 13 insertions(+), 11 deletions(-) diff --git a/net/tipc/socket.c b/net/tipc/socket.c index 333c5da..800caaa 100644 --- a/net/tipc/socket.c +++ b/net/tipc/socket.c @@ -441,15 +441,19 @@ static void __tipc_shutdown(struct socket *sock, int error) while ((skb = __skb_dequeue(&sk->sk_receive_queue)) != NULL) { if (TIPC_SKB_CB(skb)->bytes_read) { kfree_skb(skb); - } else { - if (!tipc_sk_type_connectionless(sk) && - sk->sk_state != TIPC_DISCONNECTING) { - tipc_set_sk_state(sk, TIPC_DISCONNECTING); - tipc_node_remove_conn(net, dnode, tsk->portid); - } - tipc_sk_respond(sk, skb, error); + continue; + } + if (!tipc_sk_type_connectionless(sk) && + sk->sk_state != TIPC_DISCONNECTING) { + tipc_set_sk_state(sk, TIPC_DISCONNECTING); + tipc_node_remove_conn(net, dnode, tsk->portid); } + tipc_sk_respond(sk, skb, error); } + + if (tipc_sk_type_connectionless(sk)) + return; + if (sk->sk_state != TIPC_DISCONNECTING) { skb = tipc_msg_create(TIPC_CRITICAL_IMPORTANCE, TIPC_CONN_MSG, SHORT_H_SIZE, 0, dnode, @@ -457,10 +461,8 @@ static void __tipc_shutdown(struct socket *sock, int error) tsk->portid, error); if (skb) tipc_node_xmit_skb(net, skb, dnode, tsk->portid); - if (!tipc_sk_type_connectionless(sk)) { - tipc_node_remove_conn(net, dnode, tsk->portid); - tipc_set_sk_state(sk, TIPC_DISCONNECTING); - } + tipc_node_remove_conn(net, dnode, tsk->portid); + tipc_set_sk_state(sk, TIPC_DISCONNECTING); } } -- 2.7.4 ------------------------------------------------------------------------------ Developer Access Program for Intel Xeon Phi Processors Access to Intel Xeon Phi processor-based developer platforms. With one year of Intel Parallel Studio XE. Training and support from Colfax. Order your platform today.http://sdm.link/intel _______________________________________________ tipc-discussion mailing list tipc-discussion@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/tipc-discussion