From: Jon Maloy <[email protected]> Date: Tue, 17 Apr 2018 21:58:27 +0200
> From: Tung Nguyen <[email protected]> > > When configuring the number of used bearers to MAX_BEARER and issuing > command "tipc link monitor summary", the command enters infinite loop > in user space. > > This issue happens because function tipc_nl_node_dump_monitor() returns > the wrong 'prev_bearer' value when all potential monitors have been > scanned. > > The correct behavior is to always try to scan all monitors until either > the netlink message is full, in which case we return the bearer identity > of the affected monitor, or we continue through the whole bearer array > until we can return MAX_BEARERS. This solution also caters for the case > where there may be gaps in the bearer array. > > Signed-off-by: Tung Nguyen <[email protected]> > Signed-off-by: Jon Maloy <[email protected]> Applied. ------------------------------------------------------------------------------ Check out the vibrant tech community on one of the world's most engaging tech sites, Slashdot.org! http://sdm.link/slashdot _______________________________________________ tipc-discussion mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/tipc-discussion