Frank, “Must” is a strong word. What goes wrong if you cross them?
73, Carl WS7L On Thu, Nov 5, 2020 at 9:47 PM <donov...@erols.com> wrote: > Hi Bob, > > > While bonding the radials is desirable, its not essential. But you > must NOT cross the radials over each other. > > > ... > 73 > Frank > W3LPL > > > > > > ----- Original Message ----- > > From: "Robert L. Chortek" <robert.chor...@berliner.com> > To: "TopBand List" <topband@contesting.com> > Sent: Friday, November 6, 2020 2:05:43 AM > Subject: Topband: OT - Bonding Radials at Intersections > > I just finished installing a two element vertical array on 40M. The > instructions say to bond the radials from one vertical where they intersect > with a radial for the other vertical. > > My question is, is this really necessary and what effect would doing so > (or not) have on the performance of the Array? > > Much appreciated. > > 73, > > Bob AA6VB > > Bob > Robert L. Chortek > _________________ > Searchable Archives: http://www.contesting.com/_topband - Topband > Reflector > > _________________ > Searchable Archives: http://www.contesting.com/_topband - Topband > Reflector > _________________ Searchable Archives: http://www.contesting.com/_topband - Topband Reflector