** Package changed: plasma-pa (Ubuntu) => pulseaudio (Ubuntu)

-- 
You received this bug notification because you are a member of Ubuntu
Touch seeded packages, which is subscribed to pulseaudio in Ubuntu.
https://bugs.launchpad.net/bugs/1716092

Title:
  Enabling Auto switching streams on new active output causes pulseaudio
  to crash

Status in pulseaudio package in Ubuntu:
  New

Bug description:
  Not sure if this is a plasma-pa bug or a pulseaudio bug.  In plasma-pa
  -> Audio Volumue -> Advanced tab.... checking the "Automatically
  switch all running streams when a new output becomes available" cause
  PA to crash.  If the /etc/pulse/default.pa file is modified by
  commenting out following line:

    load-module module-switch-on-connect

  PA will start as expected.  I have not checked to see if the auto
  switching works when the default.pa line is commented out.

  ProblemType: Bug
  DistroRelease: Ubuntu 17.10
  Package: plasma-pa 4:5.10.5-0ubuntu1
  ProcVersionSignature: Ubuntu 4.12.0-12.13-generic 4.12.8
  Uname: Linux 4.12.0-12-generic x86_64
  ApportVersion: 2.20.7-0ubuntu1
  Architecture: amd64
  CurrentDesktop: KDE
  Date: Fri Sep  8 23:07:29 2017
  InstallationDate: Installed on 2016-11-15 (298 days ago)
  InstallationMedia: Kubuntu 16.10 "Yakkety Yak" - Release amd64 (20161012.1)
  SourcePackage: plasma-pa
  UpgradeStatus: Upgraded to artful on 2017-08-27 (12 days ago)

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/pulseaudio/+bug/1716092/+subscriptions

-- 
Mailing list: https://launchpad.net/~touch-packages
Post to     : touch-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~touch-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to