Question 1) Monitor is plugged in on standard VGA connector (15 pin
D-Sub). I guess it does not matter which monitor type. I have done it
with a Ilyama ProLite G2773HS and a Samsung Syncmaster S24B350 monitor.

As soon as the monitors are configured, for example the external monitor
as replacement for the built in LCD-display of a notebook, the system
detects this configuration next time automatically and is switching to
the proper monitor configuration, also for the login-screen. This
behavior is fine, but does not help the first time, when no
configuration was done (or it falls back to the starting situation).

Question 2) I am using the P/N: U3DUALADA (barcode D16-00352296).

Question 3) As HDMI monitor I am using the Samsung Syncmaster S24B35

Question 4) Using the i-tec adapter for the additional Samsung
Syncmaster S24B350 monitor was working without any problems on Ubuntu
16.04. On Ubuntu 18.04 monitor configuration is not automatically
detected. As work-arround I open the configuration->devices->displays
dialog. If this dialog is open and I reconnect the i-tec adapter, the
system offers now configuration possibilities. This must be done every
time the adpater is connected to the system. A second minor problem when
using this adapter is a mouse flickering effect. When mouse icon
changes, it mouse icon disappears completely for a short time. When
disconnecting the adapter system finds back to the default monitor
situation without problems.

-- 
You received this bug notification because you are a member of Ubuntu
Touch seeded packages, which is subscribed to xorg in Ubuntu.
https://bugs.launchpad.net/bugs/1773484

Title:
  Login screen not moved to used monitor

Status in xorg package in Ubuntu:
  Incomplete

Bug description:
  On Ubuntu 16.04 the login screen and system menu bar, ... is moved to
  the monitor where the mouse pointer is located. On Ubuntu 18.04 login
  dialog and system menues are restricted to the main monitor.

  So if you have a notebook with defect lcd display you can work with it
  using Ubuntu 16.04 and an external monitor, but you cannot work with
  Ubuntu 18.04, because you are not able to login!

  This problem was also asked on:
  
https://askubuntu.com/questions/1031808/problem-with-login-screen-with-dual-monitor-on-ubuntu-18-04

  ProblemType: Bug
  DistroRelease: Ubuntu 18.04
  Package: xorg 1:7.7+19ubuntu7
  ProcVersionSignature: Ubuntu 4.15.0-22.24-generic 4.15.17
  Uname: Linux 4.15.0-22-generic x86_64
  ApportVersion: 2.20.9-0ubuntu7
  Architecture: amd64
  BootLog: Error: [Errno 13] Keine Berechtigung: '/var/log/boot.log'
  CompositorRunning: None
  CurrentDesktop: ubuntu:GNOME
  Date: Sat May 26 07:04:47 2018
  DistUpgraded: Fresh install
  DistroCodename: bionic
  DistroVariant: ubuntu
  EcryptfsInUse: Yes
  ExtraDebuggingInterest: Yes
  GraphicsCard:
   Intel Corporation Haswell-ULT Integrated Graphics Controller [8086:0a16] 
(rev 0b) (prog-if 00 [VGA controller])
     Subsystem: Lenovo Haswell-ULT Integrated Graphics Controller [17aa:220c]
  InstallationDate: Installed on 2018-04-30 (25 days ago)
  InstallationMedia: Ubuntu 18.04 LTS "Bionic Beaver" - Release amd64 (20180426)
  MachineType: LENOVO 20AQ007TGE
  ProcEnviron:
   TERM=xterm-256color
   PATH=(custom, no user)
   XDG_RUNTIME_DIR=<set>
   LANG=de_AT.UTF-8
   SHELL=/bin/bash
  ProcKernelCmdLine: BOOT_IMAGE=/boot/vmlinuz-4.15.0-22-generic 
root=UUID=28805c99-e27d-49f9-a2e5-17f85980a6d6 ro quiet splash vt.handoff=1
  SourcePackage: xorg
  Symptom: display
  UpgradeStatus: No upgrade log present (probably fresh install)
  dmi.bios.date: 05/20/2014
  dmi.bios.vendor: LENOVO
  dmi.bios.version: GJET77WW (2.27 )
  dmi.board.asset.tag: Not Available
  dmi.board.name: 20AQ007TGE
  dmi.board.vendor: LENOVO
  dmi.board.version: SDK0E50510 PRO
  dmi.chassis.asset.tag: No Asset Information
  dmi.chassis.type: 10
  dmi.chassis.vendor: LENOVO
  dmi.chassis.version: Not Available
  dmi.modalias: 
dmi:bvnLENOVO:bvrGJET77WW(2.27):bd05/20/2014:svnLENOVO:pn20AQ007TGE:pvrThinkPadT440s:rvnLENOVO:rn20AQ007TGE:rvrSDK0E50510PRO:cvnLENOVO:ct10:cvrNotAvailable:
  dmi.product.family: ThinkPad T440s
  dmi.product.name: 20AQ007TGE
  dmi.product.version: ThinkPad T440s
  dmi.sys.vendor: LENOVO
  version.compiz: compiz N/A
  version.libdrm2: libdrm2 2.4.91-2
  version.libgl1-mesa-dri: libgl1-mesa-dri 18.0.0~rc5-1ubuntu1
  version.libgl1-mesa-glx: libgl1-mesa-glx 18.0.0~rc5-1ubuntu1
  version.xserver-xorg-core: xserver-xorg-core 2:1.19.6-1ubuntu4
  version.xserver-xorg-input-evdev: xserver-xorg-input-evdev N/A
  version.xserver-xorg-video-ati: xserver-xorg-video-ati 1:18.0.1-1
  version.xserver-xorg-video-intel: xserver-xorg-video-intel 
2:2.99.917+git20171229-1
  version.xserver-xorg-video-nouveau: xserver-xorg-video-nouveau 1:1.0.15-2

To manage notifications about this bug go to:
https://bugs.launchpad.net/ubuntu/+source/xorg/+bug/1773484/+subscriptions

-- 
Mailing list: https://launchpad.net/~touch-packages
Post to     : touch-packages@lists.launchpad.net
Unsubscribe : https://launchpad.net/~touch-packages
More help   : https://help.launchpad.net/ListHelp

Reply via email to