On Sun, Aug 06, 2017 at 09:54:15PM -0500, Jiandi An wrote:
> static int __maybe_unused crb_go_idle(struct device *dev, struct crb_priv
> *priv)
> {
> - if ((priv->flags & CRB_FL_ACPI_START) ||
> - (priv->flags & CRB_FL_CRB_SMC_START))
> + if (!(priv->flags & CRB_FL_CRB_START))
I think it would be better to have these list the cases where go_idle
is known to be required. Less brittle that way..
if ((priv->flags & (CRB_FL_ACPI_START | CRB_FL_CRB_START)) == 0)
return 0
> - if (!(priv->flags & CRB_FL_ACPI_START)) {
> + if (priv->flags & CRB_FL_CRB_START) {
Eg like this now makes more sense, assumming CRB_START is the right
test :)
Jason
------------------------------------------------------------------------------