To fix the clock divider calculation error when the controller
clock same as the operating frequency. This is known as bypass
mode. In this mode, the divider should be 0.

Signed-off-by: Chin Liang See <cl...@altera.com>
Cc: Pantelis Antoniou <pa...@antoniou-consulting.com>
Cc: Rajeshwari Shinde <rajeshwar...@samsung.com>
Cc: Jaehoon Chung <jh80.ch...@samsung.com>
Cc: Mischa Jonker <mjon...@synopsys.com>
---
 drivers/mmc/dw_mmc.c |    5 ++++-
 1 file changed, 4 insertions(+), 1 deletion(-)

diff --git a/drivers/mmc/dw_mmc.c b/drivers/mmc/dw_mmc.c
index 5bf36a0..0df30bc 100644
--- a/drivers/mmc/dw_mmc.c
+++ b/drivers/mmc/dw_mmc.c
@@ -245,7 +245,10 @@ static int dwmci_setup_bus(struct dwmci_host *host, u32 
freq)
                return -EINVAL;
        }
 
-       div = DIV_ROUND_UP(sclk, 2 * freq);
+       if (sclk == freq)
+               div = 0;        /* bypass mode */
+       else
+               div = DIV_ROUND_UP(sclk, 2 * freq);
 
        dwmci_writel(host, DWMCI_CLKENA, 0);
        dwmci_writel(host, DWMCI_CLKSRC, 0);
-- 
1.7.9.5

_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot