Even u-boot boots up, the pcie link may not setup correctly when
Freescale SOC acts as endpoint.
So change the link status from 'no link' to 'undetermined' to
reduce the confusion.
The link status can check from host side eventually.

Signed-off-by: Roy Zang <tie-fei.z...@freescale.com>
---
 drivers/pci/fsl_pci_init.c |   10 ++++++++--
 1 file changed, 8 insertions(+), 2 deletions(-)

diff --git a/drivers/pci/fsl_pci_init.c b/drivers/pci/fsl_pci_init.c
index 3a41b0e..231b075 100644
--- a/drivers/pci/fsl_pci_init.c
+++ b/drivers/pci/fsl_pci_init.c
@@ -504,8 +504,14 @@ void fsl_pci_init(struct pci_controller *hose, struct 
fsl_pci_info *pci_info)
                }
 #endif
                if (!enabled) {
-                       /* Let the user know there's no PCIe link */
-                       printf("no link, regs @ 0x%lx\n", pci_info->regs);
+                       /* Let the user know there's no PCIe link for root
+                        * complex. for endpoint, the link may not setup, so
+                        * print undetermined.
+                        */
+                       if (fsl_is_pci_agent(hose))
+                               printf("undetermined, regs @ 0x%lx\n", 
pci_info->regs);
+                       else
+                               printf("no link, regs @ 0x%lx\n", 
pci_info->regs);
                        hose->last_busno = hose->first_busno;
                        return;
                }
-- 
1.7.9.5

_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to