There is no need to parse PCH's <reg> property as we have already
a DM PCI API dm_pci_get_bdf() that can handle this.

Signed-off-by: Bin Meng <bmeng...@gmail.com>
---

 arch/x86/cpu/irq.c | 9 +--------
 1 file changed, 1 insertion(+), 8 deletions(-)

diff --git a/arch/x86/cpu/irq.c b/arch/x86/cpu/irq.c
index 0b36ace..cc0297f 100644
--- a/arch/x86/cpu/irq.c
+++ b/arch/x86/cpu/irq.c
@@ -86,26 +86,19 @@ static inline void fill_irq_info(struct irq_info *slot, int 
bus, int device,
 static int create_pirq_routing_table(struct udevice *dev)
 {
        const void *blob = gd->fdt_blob;
-       struct fdt_pci_addr addr;
        int node;
        int len, count;
        const u32 *cell;
        struct irq_routing_table *rt;
        struct irq_info *slot, *slot_base;
        int irq_entries = 0;
-       int parent;
        int i;
        int ret;
 
        node = dev->of_offset;
-       parent = dev->parent->of_offset;
-       ret = fdtdec_get_pci_addr(blob, parent, FDT_PCI_SPACE_CONFIG,
-                                 "reg", &addr);
-       if (ret)
-               return ret;
 
        /* extract the bdf from fdt_pci_addr */
-       irq_router.bdf = addr.phys_hi & 0xffff00;
+       irq_router.bdf = dm_pci_get_bdf(dev->parent);
 
        ret = fdt_find_string(blob, node, "intel,pirq-config", "pci");
        if (!ret) {
-- 
1.8.2.1