Hello Wenyou,

Am 02.02.2016 um 04:35 schrieb Wenyou Yang:
Due to introducing the new PLLB clock handle functions,
use these functions to clean up the PLLB enable/disable code.

Signed-off-by: Wenyou Yang <wenyou.y...@atmel.com>
Reviewed-by: Andreas Bießmann <andreas.de...@googlemail.com>
---

Changes in v3:
  - collect Reviewed-by from Andreas.

Changes in v2:
  - add return value for timeout checking at91_pllb_clk_enable/disable().

  drivers/usb/host/ohci-at91.c |   22 +++++++---------------
  1 file changed, 7 insertions(+), 15 deletions(-)

Tested-by: Heiko Schocher <h...@denx.de>

bye,
Heiko

diff --git a/drivers/usb/host/ohci-at91.c b/drivers/usb/host/ohci-at91.c
index 6ae6959..e030a0a 100644
--- a/drivers/usb/host/ohci-at91.c
+++ b/drivers/usb/host/ohci-at91.c
@@ -9,20 +9,14 @@

  #if defined(CONFIG_USB_OHCI_NEW) && defined(CONFIG_SYS_USB_OHCI_CPU_INIT)

-#include <asm/io.h>
-#include <asm/arch/hardware.h>
-#include <asm/arch/at91_pmc.h>
  #include <asm/arch/clk.h>

  int usb_cpu_init(void)
  {
-       at91_pmc_t *pmc = (at91_pmc_t *)ATMEL_BASE_PMC;
-
  #ifdef CONFIG_USB_ATMEL_CLK_SEL_PLLB
-       /* Enable PLLB */
-       writel(get_pllb_init(), &pmc->pllbr);
-       while ((readl(&pmc->sr) & AT91_PMC_LOCKB) != AT91_PMC_LOCKB)
-               ;
+       if (at91_pllb_clk_enable(get_pllb_init()))
+               return -1;
+
  #ifdef CONFIG_AT91SAM9N12
        at91_usb_clk_init(AT91_PMC_USBS_USB_PLLB | AT91_PMC_USB_DIV_2);
  #endif
@@ -45,8 +39,6 @@ int usb_cpu_init(void)

  int usb_cpu_stop(void)
  {
-       at91_pmc_t *pmc = (at91_pmc_t *)ATMEL_BASE_PMC;
-
        at91_periph_clk_disable(ATMEL_ID_UHP);

        at91_system_clk_disable(ATMEL_PMC_UHP);
@@ -58,10 +50,10 @@ int usb_cpu_stop(void)
  #ifdef CONFIG_AT91SAM9N12
        at91_usb_clk_init(0);
  #endif
-       /* Disable PLLB */
-       writel(0, &pmc->pllbr);
-       while ((readl(&pmc->sr) & AT91_PMC_LOCKB) != 0)
-               ;
+
+       if (at91_pllb_clk_disable())
+               return -1;
+
  #elif defined(CONFIG_USB_ATMEL_CLK_SEL_UPLL)
        if (at91_upll_clk_disable())
                return -1;


--
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
http://lists.denx.de/mailman/listinfo/u-boot

Reply via email to