On 09/22/2017 12:39 AM, Ran Wang wrote:
> Rx Compliance tests may fail intermittently at high
> jitter frequencies using default register values.
> 
> Program register USB_PHY_RX_OVRD_IN_HI in certain sequence
> to make the Rx compliance test pass.
> 
> Signed-off-by: Ran Wang <ran.wan...@nxp.com>
> ---


Applied to fsl-qoriq master. Thanks.

York


_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
https://lists.denx.de/listinfo/u-boot

Reply via email to