The first dhcp command consistently fails with a timeout when
the lion-rk3368 board is connected to a Zyxel GS1100-24E
Gigabit Ethernet switch:

  ethernet@ff290000 Waiting for PHY auto negotiation to complete......... 
TIMEOUT !

Increasing PHY_ANEG_TIMEOUT from the default 4000 to 8000 makes the
first dhcp command work reliably.

Signed-off-by: Jakob Unterwurzacher <jakob.unterwurzac...@theobroma-systems.com>
---
 include/configs/lion_rk3368.h | 2 ++
 1 file changed, 2 insertions(+)

diff --git a/include/configs/lion_rk3368.h b/include/configs/lion_rk3368.h
index b9c6bf8954..cae0f1ed29 100644
--- a/include/configs/lion_rk3368.h
+++ b/include/configs/lion_rk3368.h
@@ -12,5 +12,7 @@
 #define KERNEL_LOAD_ADDR               0x280000
 #define DTB_LOAD_ADDR                  0x5600000
 #define INITRD_LOAD_ADDR               0x5bf0000
+/* PHY needs longer aneg time at 1G */
+#define PHY_ANEG_TIMEOUT               8000
 
 #endif
-- 