Negative phy-addresses can occour if the caller function was not able to
determine a valid phy address (from device-tree for example). In this
case we catch this here and search for ANY phy device on the given mdio-
bus.

Signed-off-by: Hannes Schmelzer <hannes.schmel...@br-automation.com>

tr...@konsulko.com, lu...@denx.de

---

Changes in v2:
- cosmetic changes

 drivers/net/phy/phy.c | 3 ++-
 1 file changed, 2 insertions(+), 1 deletion(-)

diff --git a/drivers/net/phy/phy.c b/drivers/net/phy/phy.c
index 0c8b29d..4e8d294 100644
--- a/drivers/net/phy/phy.c
+++ b/drivers/net/phy/phy.c
@@ -922,13 +922,14 @@ struct phy_device *phy_connect(struct mii_dev *bus, int 
addr,
 #endif
 {
        struct phy_device *phydev = NULL;
+       uint mask = (addr > 0) ? (1 << addr) : 0xffffffff;
 
 #ifdef CONFIG_PHY_FIXED
        phydev = phy_connect_fixed(bus, dev, interface);
 #endif
 
        if (!phydev)
-               phydev = phy_find_by_mask(bus, 1 << addr, interface);
+               phydev = phy_find_by_mask(bus, mask, interface);
 
        if (phydev)
                phy_connect_dev(phydev, dev);
-- 
2.7.4


_______________________________________________
U-Boot mailing list
U-Boot@lists.denx.de
https://lists.denx.de/listinfo/u-boot

Reply via email to