Hi, Am 25.05.2010 10:31, schrieb prakash bedge: > Hi, > >>> Be careful. 1024 s is chip erase time, but we use sector erase only, so > it's only 3.5 seconds. > It would be really helpful if you please explain how 3.5 seconds come; since > the S29GL512P datasheet says sector erase operation time is 0.5 seconds and > program operation time is 64 microseconds.
Please see Datasheet 11.7.5: Sector Erase Time Typ = 0.5; max = 3.5 Unit = sec regards Andreas Bießmann _______________________________________________ U-Boot mailing list U-Boot@lists.denx.de http://lists.denx.de/mailman/listinfo/u-boot