On Tue, Dec 31, 2019 at 11:29:25AM +0800, mingming lee wrote: > For CMD21 tuning data, the 128/64 bytes data may coming in very > short time, before msdc_start_data(), the read data has already > come, in this case, clear MSDC_INT will cause the interrupt disappear > and lead to the thread hang. > > the solution is just clear all interrupts before command was sent. > > Signed-off-by: mingming lee <mingming....@mediatek.com>
Applied to u-boot/master, thanks! -- Tom
signature.asc