On Thu, Jan 9, 2020 at 2:50 AM Alex Marginean
<[email protected]> wrote:
>
> The helper is used to reset PHYs on connect and it determines the clause
> to use (C22/C45) based on interface type.  This fixes 'PHY reset timed out'
> warnings in console for USXGMII/XFI PHYs.
>
> Signed-off-by: Alex Marginean <[email protected]>

Acked-by: Joe Hershberger <[email protected]>