On 07.06.21 16:34, Marek Behún wrote:
Configure blinking on ethernet PHY LEDs on the MOX A board when entering
rescue mode via reset button.

Signed-off-by: Marek Behún <marek.be...@nic.cz>

Reviewed-by: Stefan Roese <s...@denx.de>

Thanks,
Stefan

---
  board/CZ.NIC/turris_mox/turris_mox.c | 35 ++++++++++++++++++++++++++++
  1 file changed, 35 insertions(+)

diff --git a/board/CZ.NIC/turris_mox/turris_mox.c 
b/board/CZ.NIC/turris_mox/turris_mox.c
index a78f33661e..44c272c7cb 100644
--- a/board/CZ.NIC/turris_mox/turris_mox.c
+++ b/board/CZ.NIC/turris_mox/turris_mox.c
@@ -377,6 +377,38 @@ int misc_init_r(void)
        return 0;
  }
+static void mox_phy_modify(struct phy_device *phydev, int page, int reg,
+                          u16 mask, u16 set)
+{
+       int val;
+
+       val = phydev->drv->readext(phydev, MDIO_DEVAD_NONE, page, reg);
+       val &= ~mask;
+       val |= set;
+       phydev->drv->writeext(phydev, MDIO_DEVAD_NONE, page, reg, val);
+}
+
+static void mox_phy_leds_start_blinking(void)
+{
+       struct phy_device *phydev;
+       struct mii_dev *bus;
+
+       bus = miiphy_get_dev_by_name("neta@30000");
+       if (!bus) {
+               printf("Cannot get MDIO bus device!\n");
+               return;
+       }
+
+       phydev = phy_find_by_mask(bus, BIT(1), PHY_INTERFACE_MODE_RGMII);
+       if (!phydev) {
+               printf("Cannot get ethernet PHY!\n");
+               return;
+       }
+
+       mox_phy_modify(phydev, 3, 0x12, 0x700, 0x400);
+       mox_phy_modify(phydev, 3, 0x10, 0xff, 0xbb);
+}
+
  static bool read_reset_button(void)
  {
        struct udevice *button, *led;
@@ -424,6 +456,9 @@ static void handle_reset_button(void)
                /* Ensure bootcmd_rescue is used by distroboot */
                env_set("boot_targets", "rescue");
+ /* start blinking PHY LEDs */
+               mox_phy_leds_start_blinking();
+
                printf("RESET button was pressed, overwriting boot_targets!\n");
        } else {
                /*



Viele Grüße,
Stefan

--
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: s...@denx.de

Reply via email to