On 03.07.21 05:08, Tony Dinh wrote:
In DM Ethernet, the old "egiga0" name is no longer valid, so replace it
with Ethernet PHY name from device tree.

Signed-off-by: Tony Dinh <mibo...@gmail.com>
---

Changes in v2:
- Correct copyright

  board/zyxel/nsa310s/nsa310s.c | 19 ++++++++-----------
  1 file changed, 8 insertions(+), 11 deletions(-)

diff --git a/board/zyxel/nsa310s/nsa310s.c b/board/zyxel/nsa310s/nsa310s.c
index cd4a7723b1..41479af8e6 100644
--- a/board/zyxel/nsa310s/nsa310s.c
+++ b/board/zyxel/nsa310s/nsa310s.c
@@ -1,8 +1,7 @@
  // SPDX-License-Identifier: GPL-2.0+
  /*
- * Copyright (C) 2015
- * Gerald Kerma <drea...@doukki.net>
- * Tony Dinh <mibo...@gmail.com>
+ * Copyright (C) 2015, 2021 Tony Dinh <mibo...@gmail.com>
+ * Copyright (C) 2015 Gerald Kerma <drea...@doukki.net>
   */
#include <common.h>
@@ -81,22 +80,18 @@ int board_init(void)
        return 0;
  }
+#define PHY_ADR 1
+

Please read the PHY address from the DT instead. It's encoded in the
"reg" property and should be able to read it from there. No need to
double define this value here again.

Thanks,
Stefan

  #ifdef CONFIG_RESET_PHY_R
  void reset_phy(void)
  {
        u16 reg;
-       u16 phyaddr;
-       char *name = "egiga0";
+       u16 phyaddr = PHY_ADR;
+       char *name = "ethernet-controller@72000";
if (miiphy_set_current_dev(name))
                return;
- /* read PHY dev address */
-       if (miiphy_read(name, 0xee, 0xee, (u16 *) &phyaddr)) {
-               printf("could not read PHY dev address\n");
-               return;
-       }
-
        /* set RGMII delay */
        miiphy_write(name, phyaddr, MV88E1318_PGADR_REG, MV88E1318_MAC_CTRL_PG);
        miiphy_read(name, phyaddr, MV88E1318_MAC_CTRL_REG, &reg);
@@ -131,5 +126,7 @@ void reset_phy(void)
        /* downshift */
        miiphy_write(name, phyaddr, 0x10, 0x3860);
        miiphy_write(name, phyaddr, 0x0, 0x9140);
+
+       printf("MV88E1318 PHY initialized on %s\n", name);
  }
  #endif /* CONFIG_RESET_PHY_R */



Viele Grüße,
Stefan

--
DENX Software Engineering GmbH,      Managing Director: Wolfgang Denk
HRB 165235 Munich, Office: Kirchenstr.5, D-82194 Groebenzell, Germany
Phone: (+49)-8142-66989-51 Fax: (+49)-8142-66989-80 Email: s...@denx.de

Reply via email to