On 3/2/22 11:49, Pali Rohár wrote:
Variable msg_req_delay is set but never used. So completely remove it.

Signed-off-by: Pali Rohár <p...@kernel.org>

Reviewed-by: Stefan Roese <s...@denx.de>
Tested-by: Stefan Roese <s...@denx.de>

Thanks,
Stefan

---
  tools/kwboot.c | 7 +------
  1 file changed, 1 insertion(+), 6 deletions(-)

diff --git a/tools/kwboot.c b/tools/kwboot.c
index 5a7c53ce8929..4dfb1038b4ff 100644
--- a/tools/kwboot.c
+++ b/tools/kwboot.c
@@ -48,11 +48,9 @@ static unsigned char kwboot_msg_debug[] = {
  };
/* Defines known to work on Kirkwood */
-#define KWBOOT_MSG_REQ_DELAY   10 /* ms */
  #define KWBOOT_MSG_RSP_TIMEO  50 /* ms */
/* Defines known to work on Armada XP */
-#define KWBOOT_MSG_REQ_DELAY_AXP       1000 /* ms */
  #define KWBOOT_MSG_RSP_TIMEO_AXP      1000 /* ms */
/*
@@ -285,7 +283,6 @@ static const char kwb_baud_magic[16] = "$baudratechange";
static int kwboot_verbose; -static int msg_req_delay = KWBOOT_MSG_REQ_DELAY;
  static int msg_rsp_timeo = KWBOOT_MSG_RSP_TIMEO;
  static int blk_rsp_timeo = KWBOOT_BLK_RSP_TIMEO;
@@ -1725,7 +1722,6 @@ kwboot_usage(FILE *stream, char *progname)
                "  -D <image>: boot <image> without preamble (Dove)\n");
        fprintf(stream, "  -d: enter debug mode\n");
        fprintf(stream, "  -a: use timings for Armada XP\n");
-       fprintf(stream, "  -q <req-delay>:  use specific request-delay\n");
        fprintf(stream, "  -s <resp-timeo>: use specific response-timeout\n");
        fprintf(stream,
                "  -o <block-timeo>: use specific xmodem block timeout\n");
@@ -1804,12 +1800,11 @@ main(int argc, char **argv)
                        break;
case 'a':
-                       msg_req_delay = KWBOOT_MSG_REQ_DELAY_AXP;
                        msg_rsp_timeo = KWBOOT_MSG_RSP_TIMEO_AXP;
                        break;
case 'q':
-                       msg_req_delay = atoi(optarg);
+                       /* nop, for backward compatibility */
                        break;
case 's':

Viele Grüße,